dhs Spec Intero · Fizeau interferometry

Non-contact testing of optical surfaces.

Fizeau interferometers as a module or complete measuring system – for flat surfaces, spherical optics and transmitted wavefronts. Tell us about your measurement task and we will find the right solution.

632.8 nm HeNe laser
Beam diameter up to 102 mm
Zoom up to 6×
One point of contact through to service
Fizeau-Interferometer dhs Spec Intero 100 und Intero 40
The challenge

Test flatness and form precisely – without compromise.

Optical surfaces must be tested without contact and reproducibly – in the lab as well as on the test bench. But complete systems don’t fit every measurement setup, integrators often lack the right module, and there are too many contacts between consulting and service.

Step 1

Define the measurement task

Test object, tolerances, environment and desired evaluation – we advise you personally.

Option A

Module

For integrators, OEMs and laboratories with their own measurement setup – directly from dhs.

Option B

Complete system

The fully assembled interferometer – provided through our integration partner.

Four modules. Two sizes.

Each size is available as analog (A) for visual fringe evaluation or digital (D) with camera and USB connection.

dhs Spec Intero 40
Compact

dhs Spec Intero 40

For smaller optics and components – with a particularly compact design for integration into test benches.

Beam diameter 38 mm
Zoom 3× / 6×, focus range ±1.5 m
Versions Intero 40 A and 40 D
Housing 160 × 170 mm (W × H), approx. 7.25 kg
dhs Spec Intero 100
Large aperture

dhs Spec Intero 100

The standard for flat optics and components up to 4″ – in optics manufacturing, incoming inspection and the lab.

Beam diameter 102 mm
Zoom 1× to 6×, focus range ±2.0 m
Versions Intero 100 A and 100 D
Housing 190 × 226 mm (W × H), approx. 14 kg

Analog or digital?

Each size is available in two versions. We advise you on which one suits your measurement task. We also offer maintenance, adjustment, spare parts and training for existing interferometers of the FI series.

Analog (A)
Visual evaluation
Video output (BNC, adapter to RCA) – connects directly to a monitor
Digital (D)
Evaluation on a computer
one USB connection – no frame grabber, works with a laptop
Operation
Zoom, focus, attenuator
plus beam aperture, conveniently operated from above
Cameras (D)
Two CMOS cameras
for measuring and alignment
Evaluation (D)
static and phase-shifting
prepared for both methods
Price
on request
module or complete system
Measuring principle

How a Fizeau interferometer measures.

Reference and test beam overlap to form a fringe pattern. Each fringe corresponds to a height difference of half a wavelength – at 632.8 nm, that is 0.3164 µm.

Laserstrahl wird an der Referenzfläche teilweise reflektiert und am Prüfling zurückgeworfen; beide Strahlen überlagern sich zum Interferogramm
01

Expand the beam

The HeNe laser beam is expanded and emitted as a collimated beam.

02

Create the reference

The reference surface (TF or TS) reflects a small portion back.

03

Two-point alignment

Reference and test object are quickly aligned to each other using the crosshair.

04

Read the interferogram

The fringes show the form deviation like contour lines on a map.

What you can measure.

One module, many measurement configurations – with the right reference optics and mounts.

streifen-planflaeche

Flat surfaces

Flatness of windows, mirrors and reference surfaces – straight fringes indicate a flat surface.

streifen-sphaere

Spherical surfaces & radius

Form deviation of convex and concave optics; radius of curvature via cat’s eye and confocal position.

streifen-planparallele-platte

Plane-parallel plates

Parallelism and both sides of a plate – with clean separation of the reflections.

streifen-wellenfront

Transmitted wavefront

Homogeneity and stresses in the material, measured in transmission against a reference mirror.

streifen-reflektierend

Highly reflective surfaces

With an optical attenuator for optimal fringe contrast, even with highly reflective test objects.

streifen-prismen

Prisms & components

Testing of optical components and assemblies in production and incoming inspection.

Technical data.

Both sizes in direct comparison – for the analog and the digital version.

Operation
15 to 30 °C
5 to 95 % rel. humidity, non-condensing
Optimal measurement
20 to 23 °C
fluctuation below 1 °C per 15 minutes
Installation
Vibration isolation
recommended for 1 to 120 Hz
Power supply
115 / 230 V AC
automatic switching
MerkmalIntero 40 A / DIntero 100 A / D
Strahldurchmesser38 mm102 mm (4″)
Zoom3× / 6×1× bis 6×
Fokusbereich±1,5 m±2,0 m
BildausgabeA: Video (BNC) · D: USBA: Video (BNC) · D: USB
Kameraauflösung (D)640×480 / 1k×1k640×480 / 1k×1k
LaserHeNe 632,8 nm, Klasse 2HeNe 632,8 nm, Klasse 2
Genauigkeit*λ/100λ/100
Wiederholgenauigkeit*ca. 0,1 nm RMSca. 0,1 nm RMS
Höhenauflösung*λ/8000λ/8000
Gehäuse B × H160 × 170 mm190 × 226 mm
Füßehöhenverstellbar 40–60 mmhöhenverstellbar 40–60 mm
Gewichtca. 7,25 kgca. 14 kg

* Werte bei digitaler, phasenschiebender Auswertung. Auswertesoftware ist nicht Teil des Moduls.

Tell us about your measurement task.

We will get back to you personally and clarify whether a module or a complete system is the right solution.

By submitting, you agree to the processing of your data for the purpose of handling your inquiry. More information in our privacy policy.
Thank you for your inquiry. We will get back to you personally within two working days.
Something went wrong while sending. Please try again or email us at vertrieb@dhssolution.com.